Home > Products > Point Level Measurement > Roto-Bin-Dicator® > Super-Safe-Plus
Fail-Safe Operation
   Optical sensor monitors the movement of the shaft. If the shaft stops
   turning for any reason, the unit will alarm. Provides notification of
   failure due to power loss, open or shorted motor circuit, component
   failure, mechanical failure of the motor or clutch in either high or low
   level applications

Lights on Enclosure Cover
   Green LED indicates power and operation status; red LED indicates
   alarm and failure status

External Function Test
   Magnetic fob can be used to test the unit without removing the cover
   while it is installed and operating